Sign In | Join Free | My himfr.com
Home > Portable Energy Meter Test Equipment >

HS3303 Three Phase Portable Static Meter Test Bench(Electricity Meter Test)

    Buy cheap HS3303 Three Phase Portable Static Meter Test Bench(Electricity Meter Test) from wholesalers
     
    Buy cheap HS3303 Three Phase Portable Static Meter Test Bench(Electricity Meter Test) from wholesalers
    • Buy cheap HS3303 Three Phase Portable Static Meter Test Bench(Electricity Meter Test) from wholesalers

    HS3303 Three Phase Portable Static Meter Test Bench(Electricity Meter Test)

    Ask Lasest Price
    Brand Name : Shengdi
    Certification : SGS,CNAS
    Model Number : HS3303
    Price : USD$1~100000/SET
    Delivery Time : 35days
    Payment Terms : T/T.L/C
    Supply Ability : 3000 sets/Years
    • Product Details
    • Company Profile

    HS3303 Three Phase Portable Static Meter Test Bench(Electricity Meter Test)

    HS3303 Portable 3 Phase Energy Meter Test Bench


    Technical specification


    1. Electrical output
    1) Voltage and current measurement range
    Output voltage ranges: 57.7V/63.5V and 220V/240V (480V option)
    Output current ranges: 0.1A, 1A, 5A, 20A, and 100A
    2) Output load capacity
    Voltage loop: Max. 50VA
    Current loop: Max 100VA (Measurement range 100A)
    2. Electrical output adjustment
    1) Voltage adjustment
    a) Adjustment range: 0%~125% selected voltage range
    b) Adjustment fineness: four finenesses as 10%, 1%, 0.1%, and 0.01% are
    available
    c) Max. output voltage: 300V or 600V
    2) Current adjustment
    a) Adjustment range: 0%~120% selected current range
    b) Adjustment fineness: four finenesses as 10%, 1%, 0.1%, and 0.01% are
    available
    c) Max. output current: 120A
    3) Phase adjustment
    a) Adjustment fineness: 0°~359.99°
    b) Adjustment fineness: four finenesses as 10°, 1°, 0.1°, and 0.01° are
    available
    3. Voltage and current output distortion
    This device’s voltage and current output distortion will not be more than 1%
    (testing under linear load)
    4. Output power stability
    This device’s pre-set output power will not exceed 0.05% compared with the
    measurement range variation within 180S.
    5. ymmetry of electrical outputs from three phases
    The difference between any line or phase voltage and its average will not be
    Technical specification
    - 1 -more than 0.2%; the difference between any phase current and its average will
    not be more than 0.2%; the phase difference between any phase current and its
    corresponding phase voltage will not be more than 0.2%.
    6. Harmonic content
    a) Number of harmonic waves: 2~31
    b) Harmonic content: less than 40% (compared with fundamental wave)
    c) Harmonic phase: 0°~359.99°
    7. Monitoring instrument
    To be read directly from the standard meter.
    8. Electric pulse
    Electric pulse output from standard meter:
    1) For error calculator to calculate the error of any meter to be tested;
    2) For the reference of upper-level measurement examination and
    determination agency when sending the standard meter to them for testing.
    Please refer to standard meter’s Table of Constants for pulse constants.
    9. Power supply
    Single-phase AC 220V/240V (100V/110V/230V is also applicable), 50/60Hz,
    max. input power consumption: 500W.


    Wooden Packing Details

    HS3303 Portable Three Phase Energy Meter Test Bench

    Weight: G.W 160KG

    Size: 1450*750*1600 mm

    HS3303 Three Phase Portable Static Meter Test Bench(Electricity Meter Test)

    HS3303 Three Phase Portable Static Meter Test Bench(Electricity Meter Test)

    Quality HS3303 Three Phase Portable Static Meter Test Bench(Electricity Meter Test) for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Zhejiang Shengdi Technology Inc.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)