HS-9503 Three Phase Isolated Current Transformer(For Close Link Meter Test Bench)

    Buy cheap HS-9503 Three Phase Isolated Current Transformer(For Close Link Meter Test Bench) from wholesalers
     
    Buy cheap HS-9503 Three Phase Isolated Current Transformer(For Close Link Meter Test Bench) from wholesalers
    • Buy cheap HS-9503 Three Phase Isolated Current Transformer(For Close Link Meter Test Bench) from wholesalers

    HS-9503 Three Phase Isolated Current Transformer(For Close Link Meter Test Bench)

    Ask Lasest Price
    Brand Name : Shengdi Electrical
    Certification : ISO9001:2008
    Model Number : HS9503
    Price : USD$1~100000/SET
    Delivery Time : 15 days
    Payment Terms : TT/LC
    Supply Ability : 300
    • Product Details
    • Company Profile

    HS-9503 Three Phase Isolated Current Transformer(For Close Link Meter Test Bench)

    HS-9503 Three Phase Isolated Current Transformer
    Technical Specifications


    HS-9503 Three Phase Isolated Current Transformer(For Close Link Meter Test Bench)


    Pic 1 the method of connection of isolated CT picture

    When you test the return circle of three phase meter, the current and voltage are closed links, which you need to isolate them. As for the multi-position power meter auto-calibration system, it should add the three phase isolated current transformer: HS-9503.

    At present, this kind of testing return circle current and voltage closed links power meter, and widely used in productive and application, even the numbers are still amplified. If the connection I-P of testing return circle cant divided the current and voltage ,and through the circle it make the failed connection for every verified meters.

    Therefore, the return current through the isolated transformer to separate , in order to improve the efficient of verifying and testing , as for the isolated connection energy meter, sometimes also hope testing them during the unisolated condition.

    Phase should install the isolated transformer on each verified energy meter position.

    The variable percentage of isolating transformer is 1:1, and phase place its error enough small range have in the whole range, can bring the obvious additional error in measuring.

    Main Characteristics

    Wide electric current range:0.05A 120A;

    Maximum transmission power: max. 60VA;

    •Adopt the electronic error to compensate, guarantee accuracy;

    •Overload indication.

    Range of Application

    At multi-position check-up device , measure electric current and voltage return circuit can separating or electric energy meter not separated;

    Carry on the transformation to the existing check-up device.

    Ordinary Index

    Auxiliary voltage:220V±15% 50/60Hz±5%, max. 10VA.

    Machine case: The metal case body assembles three and isolates the transformer of electric current.

    Weight: 14.5kg.

    Working environment tempreture:+10~+40.

    Function environment tempreture:-10~+50.

    Store tempreture:-40~+80.

    Transformational Index

    Nominal frequency:50Hz/60Hz±5%

    Elementary current:0.05~120A

    Secondary current:0.05~120A

    Output load

    Output power: max. 60VA.

    Output load:

    Output range:0.05~1A 0.5Ω.

    Outputrage:1~120A 0.5V divided by the present current value.

    Output load voltage: max 0.5V.

    Error

    transformation ratio error :0.05%.

    Angular Error :1min.

    Active power error :0.10%(COSφ=0.5C~1~0.5L).

    P1,P2,P3:

    Radiation the indicator lamp is shine: this circle is normal; otherwise the light is dim: it means that the circle is abnormal .

    PRO: warning the output outlet, I1, I2, I3 relevant current return circle output the warning signal (Lead the notice to export alertly) I1-I,I2-I,I3-I: isolated CT current input the terminal for one time.

    I1-COM,I2-COM,I3-COM isolated CT current input the terminal for primary.

    I1-o, I2-o, I3-o: isolated Ct current output the terminal for second time.

    COM1, COM2, COM3 isolated CT current output the terminal for second time.

    Several isolated CT connect the first time connect each other,and at second time to solo test the return circuit of power supply

    Dimension:200mm×220mm×220mm.

    Contact: Yeli

    Email: hysdsales@gmail.com

    Skype: lily19850618


    Quality HS-9503 Three Phase Isolated Current Transformer(For Close Link Meter Test Bench) for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Zhejiang Shengdi Technology Inc.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)